View and download drager xam 5600 technical handbook online. This triangle in warnings identifies the options available for avoiding the hazard. The drager xam 7000 monitor combines electrochemical ec, catalytic oxida tion c. Both portable gas detectors are designed for clearance measurements in. Drager xam 7000 st652006 drager xam 7000 is the innovative solution for the simultaneous and continuous measurement of up to five gases. The instrument is set to the bump test function, see section 3. Drager x am pump external pump for multigas detectors the drager x am pump is an external pump for the portable gas detectors drager x am 2500, 5000, and 5600 designed for clearance measurement, for example in tanks and shafts. Drager xam 5000 security sensors technical manual pdf view.
The drager xam 2500 was especially developed for use as personal. Get indepth information on draeger xam 7000 detectors including detailed technical specifications and product datasheets. The drager xam 7000 can be equipped with three electrochemical, and two catalytic bead or infrared sensors. Any use of the drger x am 7000 requires full understanding and strict observation of these instructions and the sensor datasheets. The robust 2 to 4 gas detector drager x am 3000 continually monitors h2s, co, o2 and combustible gases in the ambient air. X am 5000 analyseinstrumente pdf anleitung herunterladen. An optional, integrated pump or data logger can also be included.
A version of the ccvision software that can be used for drager x am 2500 is available for download from the product page for the x am 2500 at the following web address. Draeger xam 7000 detector specifications draeger detectors. Consult drager safetys entire drager x am 7000 catalogue on directindustry. The explosionprotection approvals are only valid for the xam. Alarm conditions can not be ignored because of the extremely loud multitone horn. See the drager x am 7000 technical manual for details of how to activate and deactivate press and hold the keys and. Database contains 5 drager x am 5000 manuals available for free online viewing or downloading in pdf.
The user is responsible for determining the suitability of this product. Innovative signaling design and handy assistant functions ensure complete safety throughout the process. The drager xam 7000 is the innovative solution for the simultaneous and continuous detection of up to five gases. Pac 7000 pac 8xx0 x am 2000 x am 2500 x am 5000 x am 5600 x am 3500 x am 8000. For your safety strictly follow the instructions for use indicates an imminently hazardous situation which, if not 1 any use of the device requires full.
The drager xam 7000 provides simultaneous and continuous measurement of up to five gases. The explosionprotection approvals are only valid for the xam 5600. Seafarers technical guide for marine engineersnitrogen generator. Drager xam7000 is the solution for the simultaneous and continuous measurement of up to five gases.
Drager xam 7000 drager safety pdf catalogs technical. X am 110017002000 8 x am 3000 4 x am 7000 pid sensor 6. Drager x am pump the drager x am pump is an external pump for the portable gas detectors drager x am 2500, 5000, and 5600 designed for clearance measurement, for example in tanks and shafts. Order highquality draeger case, for xam 7000 products at skc, inc. Drager x am 7000 is the innovative solution for the simultaneous and continuous measurement of up to five gases. Drager handbook x am 7000 technical draeger 9023727. Reliable and fully mature measuring technology, durable sensors and easy handling guarantee a high degree of safety with extremely low operating costs. In this way, the instrument can be easily adapted to various applications. The drager x am 7000, a portable measuring instrument for the simultaneous and continuous measurement of a maximum of five gases, is the ideal companion. User manuals, guides and specifications for your drager x am 5000 gas detectors, measuring instruments, monitor, security sensors. Drager xam 5000 technical manual pdf download manualslib. Drager xam 7000 monitor user manual manual pdf viewdownload.
The change from pump mode to diffusion mode is fast and easy. Drager xam 7000 is the solution for the simultaneous and. Drager pir 7000 drager safety pdf catalogs technical. For further information, see the technical handbook drager xam 7000, the sensor datasheets, and the instructions for probes. Both portable gas detectors are designed for clearance measurements. Designed for industrial use under harsh conditions. Database contains 3 drager xam 7000 manuals available for free online viewing or downloading in pdf.
The instrument is only to be used for purposes specified here. The draeger and msa bellows pumps function in the same way as the squeeze bulbs, but draw in accurate sample volumes. The easytoread color display clearly lays out all the information for you. The following video shows how to operate with the drager xam 3500 and drager 8000. Drager x am 7000, basic unit including a calibration adapter, water and dustfilter 83 17 400 in order to receive a fully operational unit, a power pack and up to 5 sensors have to be ordered. Portable gas detection instrument for the continuous monitoring of the concentration of several gases in the ambient air within the working area and in explosionhazard areas. User training drager xam 7000 series the drager x am 7000, a portable measuring instrument for the simultaneous and continuous measurement of a maximum of five gases, is the ideal companion in all situations in which the reliable monitoring of oxygen, combustible and toxic gases and vapours in the surrounding air is required. The drager x am 8000 measures up to seven toxic as well as. Maint enance the drag er xam 7000 must be inspected and serviced by trained service. Independent measurement of up to 4 gases, in accordance with the installed drager sensors. Drager xam 7000 manuals and user guides, measuring.
View and download drager xam 5000 technical manual online. The bvs 10 atex e 080 x technical suitability test is based on the adjustment with the target gas. Drager xam 2500 technical manual pdf download manualslib. Do not stick anything on the name plate on the gas detector. Both portable gas detectors are designed for clearance measurements in co.
The drager xam 7000 can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation. Aug 28, 2014 04 drager x am 7000 technical data dimensions w x h x d 150 x 140 x 75 mm. Draeger xam 8000 community, manuals and specifications. Check calibration with test gas and adjust if necessary. This symbol indicates information that may make the use of this product. Text text in bold identifies labels on the device and text on the display. Download user manual manual of drager x am 7000 measuring instruments, monitor for free or view it online on. Drager xam 7000 is the solution for the simultaneous and continuous measurement of up to. The pump automatically switches on when it is connected to a running x am device. Operation operation operation switching on the device press and hold the key for approx. Handy and durable, the drager x am 8000 is intuitive to operate singlehandedly using three function keys. During operation, it is also possible with the catalyticex sensor to change the gas being measuring or the measurement range of the sensor. It is the ideal companion in a variety of applications, such as.
Features xs sensors with 3 year warranty miniwarn exo 2 4552693 miniwarn exo 2 h 2 s 4552692 miniwarn exo 2 co 4552691. Drager xam 2500 measuring instruments technical manual pdf. All drager safety catalogs and technical brochures. Drager xam 2500 multigas detection kleinschmidt gmbh. Drager xam 7000 provides simultaneous and continuous detection of up to five gases using a combination of more than 25 available sensors. Drager xam 7000 is the innovative solution for the simultaneous and continuous detection of up to five gases. A specially designed rubber boot protects the instrument against damage even from a drop of 1. View the entire catalog of draeger xam 7000 detectors with specifications of other products from our extensive catalog from leading manufacturers of detectors. The drager x am 7000 is the innovative solution for the simultaneous and continuous. The functional design and microprocessorcontrolled digital technology of the device are precisely adjusted to the needs and requirements of personal gas warning. Drager xam 5000 manuals and user guides, gas detectors. The drager xam 7000 can be equipped with three electrochemical, and two catalytic bead, infrared or photoionisation sensors. X am 5600 measuring instruments pdf manual download. Drager x am 2500 mqg 0011 technical manual the exposure evaluation display stel for measured gases, e.
Drager xam 7000 instructions for use manual pdf download. Switching off the instrument operational characteristics switching off the instrument the alarm mute function is active. View online technical manual for drager x am 2500 measuring instruments or simply click download button to examine the drager x am 2500 guidelines offline on your desktop or laptop computer. Drager xam 7000 top 5 things you need to know frontline. The technical suitability tests are valid for the xam 5600 gas detector and the calibration cradle. Standard accessories include a sturdy shoulder strap, so you can comfortably carry the x am 8000. The explosionprotection approvals are only valid for the xam 2500 gas detection instrument. Drager x am 7000 drager x am 7000 is the innovative solution for the simultaneous and continuous measurement of up to five gases.
Drager x am 8000 multigas detector clearance measurement was never this easy and convenient. Drager xam 5600 technical handbook pdf download manualslib. To order your instrument you must configure it building each component by adding to basket. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as o2, co, no2, so2 and h2s. It is the ideal companion in a variety of applications where the reliable detection of oxygen, toxic and combustible gases and vapors are necessary. Drager xam 3500 and xam 8000 alarms chapter 0307 youtube. Drager xam 3500 and xam 8000 operation chapter 0207. The greaterthan symbol identifies a navigation path in a menu. For further information, see the technical handbook dr.
X am 5000 measuring instruments pdf manual download. Drager x am 7000 is the solution for the simultaneous and continuous measurement of up to. Technical data gases detected combustible gases, o2, co and h2s. The drager xam 7000 is the innovative solution for the simultaneous and continuous. Connect drager pac 7000 and the test gas cylinder to the calibration adapter or connect the device to the drager bump test station. The following video shows the alarm concept of the drager x am 3500 and drager x am 8000. Intended use portable gas measuring device for the continuous monitoring of the concentration of several gases in the ambient air in the working area. On delivery of the drager xam 7000, the life signal is activated, indicating that the device is functioning correctly. First, please download the pdf price list ordering guide found.
1263 389 895 1006 715 616 559 1741 1119 1572 606 850 1069 399 543 1367 768 574 1081 1096 833 389 810 55 108 672 519 1622 1300 382 604 870 550 109 621